EXPERIMENTAL STUDY OF CRACK LENGTH MEASUREMENTS USING ELECTRICAL POTENTIAL DROP METHOD

Authors

  • Hussain J.M. Al-alkawi Electromechanical Engineering Department, University of Technology/ Iraq- Baghdad.
  • Abdul Jabbar O.H. Electromechanical Engineering Department, University of Technology/ Iraq- Baghdad.
  • Maha Naji A Electrical Engineering Department, University of Technology/ Iraq- Baghdad.

DOI:

https://doi.org/10.32852/6h6q6g70

Keywords:

Constant fatigue crack length, electrical potential drop circuit(EPD), 7075-T6 Al-alloy

Abstract

The paper present some main experimental results on fatigue crack detection using Electrical Potential Drop technique (EPD) under constant stress amplitude. The potential drop electrical circuit was designed and manufactured as well as tested using the flat fatigue specimens of aluminum alloy 7075-T6. The experimental analysis showed that the electrical potential drop circuit capable for detecting the fatigue crack during the test and it gave satisfactory crack length results observation compared to the actual lengths for fatigue long cracks

Downloads

Published

2024-12-09

How to Cite

EXPERIMENTAL STUDY OF CRACK LENGTH MEASUREMENTS USING ELECTRICAL POTENTIAL DROP METHOD. (2024). THE IRAQI JOURNAL FOR MECHANICAL AND MATERIALS ENGINEERING, 23(2), 59-75. https://doi.org/10.32852/6h6q6g70